Set a thermostat to cooling mode. To do so, you must include a cooling set point in the payload, either in Celsius or Fahrenheit. For information about verifying the cooling availability of the thermostat and validating the correct set points, see HVAC Mode Constraints and Set Point Constraints.
post
https://connect.getseam.com
/thermostats/cool
/thermostats/cool
Curl
curl --request POST 'https://connect.getseam.com/thermostats/cool' \
--header 'Authorization: Bearer ${API_KEY}' \
--header 'Content-Type: application/json' \
--header 'Seam-Workspace: 00000000-0000-0000-0000-000000000000' \
--data-raw '{
"device_id": "11111111-1111-1111-1111-111111111111",
"cooling_set_point_celsius": 25
}'
device_id | type: string | ID of the Device of the thermostat |
cooling_set_point_celsius | type: number
Optional | Temperature the thermostat should cool to (in °C). You must set one of the cooling_set_point parameters |
cooling_set_point_fahrenheit | type: number
Optional | Temperature the thermostat should cool to (in °F). You must set one of the cooling_set_point parameters |
This section shows the JSON response returned by the API. Since each language encapsulates this response inside objects specific to that language and/or implementation, the actual type in your language might differ from what’s written here.
JSON
{
"action_attempt": {
"status": "pending",
"action_type": "SET_COOL",
"action_attempt_id": "22222222-2222-2222-2222-222222222222",
"result": null,
"error": null
},
"ok": true
}